Skip to content

From RED and EN 18031 to the CRA: what carries over for radio products

Radio products have met EN 18031 since August 2025; the CRA takes over on 11 December 2027. What carries over, what is new, and how old certificates count.

11 min read
  • radio equipment directive
  • red
  • en 18031
  • cyber resilience act
  • cra
  • iot
  • conformity assessment
  • connected products

Key takeaways

  • Since 1 August 2025, internet-connected radio equipment has had to protect the network, and, depending on what it processes or does, personal data and users against fraud; radio wearables, toys and childcare equipment are covered for privacy even offline. These are the requirements of the Radio Equipment Directive's delegated act, Regulation (EU) 2022/30, usually through the EN 18031 standards.
  • Delegated Regulation (EU) 2026/339 repeals that act from 11 December 2027, the day the Cyber Resilience Act (CRA) applies in full. From then, radio products are under the CRA for cybersecurity.
  • EN 18031 work covers much of the CRA's product properties (Annex I, Part I). It does not cover vulnerability handling (Part II): SBOM, disclosure, free updates for a support period, reporting.
  • RED cybersecurity type-examination certificates count under the CRA only for the risks they cover, and only until 11 June 2028, according to the Commission's guidance of 17 November 2026.
  • Radio products already have CRA duties today: the 24-hour reporting of actively exploited vulnerabilities has applied since 11 September 2026, including to radio products already on the market.

Part of a series on EU product compliance for connected-product makers. For the full calendar and who owns what, start with the map.

Radio makers have done this once already

For most makers of connected devices, the CRA is the first cybersecurity law that applies to their product. For makers of radio equipment, it is the second. Since 1 August 2025, anything with Wi-Fi, Bluetooth, cellular or another radio that connects to the internet has had to meet three essential requirements of the Radio Equipment Directive, activated by Delegated Regulation (EU) 2022/30: protecting the network, protecting personal data and privacy, and protecting against fraud.

That experience is an advantage. It is also a trap, if a company assumes the CRA is the same exercise with a new label. One of the practitioners we interviewed this month put it plainly: building only for EN 18031 is short-sighted, because the CRA absorbs the RED's cybersecurity requirements over time.

I build connected products at Ganiga, and this transition is part of our own plan. I am not a lawyer; the sources are at the end.

The timeline for a radio product

1Aug2025REDdelegatedactapplies;EN18031,withrestrictions11Sep2026CRAreportingapplies,radioproductsincluded11Dec2027CRAinfull;REDdelegatedactrepealed11Jun2028REDtype-examinationcerti¯catesstopcounting
Cybersecurity rules for a radio product, 2025 to 2028.

The change happens unit by unit, as everywhere in EU product law. Units placed on the market before 11 December 2027 stay under the RED delegated act and do not have to meet the CRA's product requirements unless they are substantially modified. Units placed from that day are under the CRA. The CRA's reporting duty, on the other hand, already covers every in-scope radio product on the market.

What the RED delegated act asked for

Delegated Regulation (EU) 2022/30 applies three essential requirements of the Radio Equipment Directive to defined categories of radio equipment:

Requirement Applies to Standard
Article 3(3)(d): no harm to the network Radio equipment that can communicate over the internet, directly or through other equipment EN 18031-1
Article 3(3)(e): personal data and privacy Internet-connected radio equipment that can process personal, traffic or location data; radio wearables, radio toys and radio equipment designed exclusively for childcare, even if not internet-connected EN 18031-2
Article 3(3)(f): protection from fraud Internet-connected radio equipment that can transfer money, monetary value or virtual currency EN 18031-3

The EN 18031 series was published by CEN-CENELEC in August 2024 and cited in the Official Journal at the end of January 2025 by Implementing Decision (EU) 2025/138, with restrictions on three subjects. The best known concerns passwords, repeated in all three standards: products relying on the options that let a user set no password, or not use one, get no presumption of conformity. The others concern the access-control options for toys and childcare equipment in EN 18031-2, and the whole assessment criteria for the secure update mechanism in EN 18031-3 (clause 6.3.2.4). In each standard, the rationale and guidance sections give no presumption either. A manufacturer can self-declare only if it applies the standards and the restrictions do not affect its product; otherwise the route is EU-type examination by a notified body (module B with C) or full quality assurance (module H).

The delegated act also leaves out radio equipment already covered by other EU rules, such as medical devices, civil aviation products, vehicles and electronic road-toll equipment, for some or all of its requirements.

The CRA repeats that pattern only for important class I products: they can self-assess only by applying in full a cited harmonised standard, a common specification or a certification scheme, and partial application brings a notified body in. Most radio products will be default products under the CRA, and those self-assess with or without a cited standard. For them, the CRA is more permissive than the RED, where not applying the cited standards meant a notified body. The classification guide covers when that applies.

What carries over, and what is new

EN 18031 is organised around security mechanisms. Most of them correspond to the product properties in Annex I, Part I of the CRA. The mapping below is my reading, not an official correspondence table; it is meant as a starting point for a gap analysis.

EN 18031 mechanism family CRA Annex I, Part I Carries over?
Access control and authentication (d) protection from unauthorised access Largely
Secure update (c) security updates Partly: the CRA adds automatic updates by default, where applicable, with opt-out
Secure storage, cryptographic keys, cryptography (e) confidentiality, (f) integrity Largely
Secure communication (e) confidentiality, (f) integrity Largely
Resilience, network monitoring, traffic control (h) availability, (i) no harm to other devices Largely
General equipment capabilities, such as no known vulnerabilities and minimal exposed services (a) no known exploitable vulnerabilities, (b) secure by default, (j) limited attack surface Partly; the guidance counts attack-surface reduction among the risks RED certificates do not cover (point 253)
Logging, deletion, user notification (EN 18031-2) (l) logging, (m) secure erasure Partly
None (g) data minimisation, (k) reduced impact of exploitation New work

"Largely" assumes you applied the relevant EN 18031 parts across all the product's assets; work done on a narrow asset scope carries over less.

And then there is everything the RED delegated act never asked for, because it regulated the product at the moment it was sold, not over its life:

  • Vulnerability handling, Annex I Part II: an SBOM per version, prompt fixes, regular testing, public disclosure of fixed vulnerabilities, a coordinated disclosure policy and contact, and free security updates.
  • A support period of at least five years, unless the product is expected to be in use for less, with an end date (month and year) stated at purchase.
  • Reporting of actively exploited vulnerabilities and severe incidents within 24 hours, already in force.
  • A cybersecurity risk assessment for the whole product, kept current, with a justification for every requirement that does not apply.
  • Classification by core functionality into default, important or critical, which decides the conformity route. The cloud back end and app that count as the product's remote data processing come into scope, but they do not change its class.

Nemko's summary is a fair one: RED work is a good start towards the CRA but not sufficient on its own. In my experience the gap is mostly process, not product: the device may already be well secured, while the organisation around it has never had to run vulnerability handling for a support period that is normally five years or more.

Old certificates under the new law

Many radio products went through a notified body for the RED delegated act, either because the EN 18031 restrictions applied or because the manufacturer chose to. The Commission's guidance of 17 November 2026 says how those certificates count:

  • a valid EU type-examination certificate for the RED cybersecurity requirements can be relied on for the risks it covers, but not beyond 11 June 2028 (points 251 and 252);
  • risks it does not cover, such as vulnerability handling, data minimisation and attack-surface reduction, must still be addressed under the CRA (point 253);
  • the certificate is evidence for the covered risks only, not proof of full CRA compliance (point 254).

The general rule behind this is Article 69(1) of the CRA: certificates under other product laws remain valid until 11 June 2028 unless they expire earlier, and manufacturers still have to carry out a full CRA risk assessment and close the gaps (points 247 to 250). Products placed on the market under the RED act stay subject to market surveillance under it after the repeal (recital 5 of Delegated Regulation 2026/339).

The standards bridge

The CRA's horizontal standards, the EN 40000 series, are being developed in CEN-CENELEC's JTC 13 and build on the EN 18031 work, according to cyberresilienceact.eu. As of 17 November 2026 none of them is cited under the CRA: EN 40000-1-1 and EN 40000-1-2 were ratified on 2 November but are not expected to be cited, and EN 40000-1-3, on vulnerability handling, is the part expected to give a presumption of conformity first.

For a radio maker, that suggests a practical approach: keep the EN 18031 test evidence, map it to Annex I Part I, and invest the new effort in Part II, where the first CRA standard is also likely to land.

What I would do this quarter

  1. List your radio products and the RED route each one took: self-declaration or notified body.
  2. Map each EN 18031 test report to the CRA's Annex I, Part I, and mark what is missing.
  3. Build Part II from scratch where needed: SBOM per version, triage records, disclosure policy, support period, update process.
  4. Check certificate dates against 11 June 2028, and plan any new assessment before then.
  5. Classify each product under the CRA by core functionality, including its app and cloud back end.
  6. Plan the unit-by-unit switch on 11 December 2027 with production and sales.

The CRA engineering guide covers Part II in depth, and the CRA operating model the transition.

Why I am writing this

I write these articles as research: to understand the sector and how companies actually run compliance day to day. They are also groundwork for a product I will probably build, to streamline how companies handle their compliance processes. If that interests you, write to me at me@bernardoforcillo.com.

Disclosure: I work on connected products at Ganiga. Nothing is for sale yet.

Frequently asked questions

When is the RED cybersecurity delegated act repealed?

Delegated Regulation (EU) 2026/339, adopted on 16 February 2026 and published in the Official Journal on 29 April 2026, repeals Delegated Regulation (EU) 2022/30 with effect from 11 December 2027, the date the Cyber Resilience Act applies in full.

Does EN 18031 compliance mean CRA compliance?

No. EN 18031 covers security properties that overlap with Annex I, Part I of the CRA, but not the vulnerability-handling requirements of Part II, such as the SBOM, disclosure policy, free security updates and the support period, nor the CRA's reporting duty. It is a strong starting point, not a substitute.

Are RED cybersecurity certificates valid under the CRA?

Partly and temporarily. According to the Commission's guidance of 17 November 2026, a valid EU type-examination certificate for the RED cybersecurity requirements can be relied on for the risks it covers until 11 June 2028. Risks it does not cover must be addressed under the CRA.

Do radio products already on the market fall under the CRA?

For reporting, yes: since 11 September 2026, manufacturers must report actively exploited vulnerabilities and severe incidents for all in-scope products, including radio products already on the market. The CRA's product requirements apply only to units placed on the market from 11 December 2027, or to older ones that are substantially modified.

What were the EN 18031 restrictions?

The EN 18031 standards were cited in the Official Journal in January 2025 with restrictions on three subjects, set by Implementing Decision (EU) 2025/138. The best known concerns password options that let users set no password or not use one; the others concern access-control options for toys and childcare equipment in EN 18031-2 and the assessment criteria for the secure update mechanism in EN 18031-3 (clause 6.3.2.4). Products relying on restricted options get no presumption of conformity and need a notified body.

Which radio products are covered by the RED delegated act?

Radio equipment that can communicate over the internet, directly or through other equipment, for network protection; internet-connected radio equipment that can process personal, traffic or location data, plus radio wearables, radio toys and radio equipment designed exclusively for childcare, for privacy; and internet-connected radio equipment that can transfer money or virtual currency, for fraud protection.

Read next

References

Checked on 20 November 2026. EUR-Lex texts and the Commission's guidance are primary sources; the rest are secondary.